Film-grade ETFE

PHYSICAL PROPERTIE

Item Unit Index Test Method/ Standards
Appearance / Semi-transparent pellets, the percentage of pellets with visible black spots shall not exceed 2% Visual inspection
Melt Flow Index g/10min 15.1~25.0 ASTM D3159

(297℃,5KG load)

Melting Point 220~230 D-3159
Specific Gravity g/cm3 1.76~1.85 HG/T 2904—1997
Rockwell Hardness HB 50~60 D-2240
Tensile Strength(23℃) Mpa 28~45 HG/T 2904—1997
Elongation at Break(23℃) % 300~450 HG/T 2904—1997
Notched Impact Strength(23℃) Ft-lb/in No Break HG/T 2904—1997
Water Absorption Rate % ≤0.03 HG/T 2902—1997
Oxygen Index % Above 50 GB/ T 2406-93
Flame Retardancy Level V-0 GB/T 2408-2008
Dielectric Constant / ≤2.4 HG/T 2904—1997
Dielectric Loss / 0.008 HG/T 2904—1997
Dielectric Breakdown Voltage(0.2mm) KV Above 7.5KV  ASTM D149
Glass Transition Temperature 80~120 DMA
Operating Temperature -50~150 UL-746

Product Description

This product features high light transmission, weather resistance, chemical corrosion resistance, V-0 flame retardancy, low surface energy, excellent mechanical toughness, and good mechanical, flame-retardant, and gas-barrier properties; additionally, it offers radiation resistance, strong adhesion to metal surfaces, and a lower density compared to other fluorinated materials.

 

Application

This product can be processed via extrusion casting or blown film extrusion into ETFE films and sheets, and is also suitable for extruding tubing, cable insulation layers, and other products.

 

Packaging

  • Packed in polyethylene plastic bags, and then sealed in outer packaging bags, each bag contains a net weight of25 kg.

 

Transportation & Storage

Transportation: During transport, protect from sunlight and moisture; keep upright and handle with care.

Storage: Store the product in a cool, well-ventilated place, away from sources of ignition and heat.

 

Attention

  1. When processing the product, appropriate personal protective equipment must be worn to eliminate safety hazards such as the inhalation of toxic gases and burns from high temperatures; open flames and smoking are strictly prohibited in the work area, and suitable exhaust systems must be installed.
  2. Products that have been opened but not yet used must be tightly sealed to prevent the entry of foreign matter.
  3. Product waste must be disposed of in accordance with relevant laws and regulations.