High-purity PFA

PHYSICAL PROPERTIE

Item Unit Index Test Method/ Standards
Appearance / Semi-transparent pellets, the percentage of pellets with visible black spots shall not exceed 5% Visual Inspection
Melt Flow Index g/10min 16.1~24.0 /
Tensile Strength (23℃) MPa 24~35 GB/T 1040.1-2018
Elongation at Break (23℃)  % 300~350 GB/T 1040.1-2018
Specific Gravity (25℃) g/cm3 2.12~2.17 GB/T 1033.1-2008
Dielectric Constant (10⁶Hz) / ≤2.1 GB/T 1409-2006
Dielectric Dissipation Factor (10⁶Hz) / ≤1×10-4 GB/T 1409-2006
Melting Point 300~310 /
Volatile Matter % ≤0.3 HG/T 2904-1997
Hardness (Shore D) Shore D 50~60 GB/T 2411-2008
Flame Retardant Rating Level V-0 GB/T 2408-2021
Limiting Oxygen Index (1.57 mm) % >95 GB/T 2406-2009

Product Description

High-purity PFA is a highly refined grade of PFA material produced using premium raw materials and cutting-edge manufacturing processes; it delivers exceptional performance, reliability, and versatility in high-tech applications. Distinguished by its outstanding chemical and heat resistance as well as superior electrical insulation properties, it is an ideal material choice for industries such as chemical processing, semiconductors, aerospace, and medical devices, offering a more economical solution for most applications that do not require high stress-crack resistance.

Application

This product is widely used in the aviation and aerospace industries, the chemical industry, high-speed cable extrusion, as well as the semiconductor and medical device sectors.

Packaging

  • Packed in polyethylene plastic bags, and then sealed in outer packaging bags, each bag contains a net weight of 25 kg.

Transportation & Storage

Transportation: During transport, protect from sunlight and moisture; keep upright and handle with care.

Storage: Store the product in a cool, well-ventilated place, away from sources of ignition and heat.

Attention

  1. When processing the product, appropriate personal protective equipment must be worn to eliminate safety hazards such as the inhalation of toxic gases and burns from high temperatures; open flames and smoking are strictly prohibited in the work area, and suitable exhaust systems must be installed.
  2. Products that have been opened but not yet used must be tightly sealed to prevent the entry of foreign matter.
  3. Product waste must be disposed of in accordance with relevant laws and regulations.